Product Details:
Payment & Shipping Terms:
|
Material: | Brass Stainless Steel | Interface Size: | 1/2" ~ 2" |
---|---|---|---|
Working Pressure: | 0.4~8 Bar | Sealing Material: | PTFE |
Interface Type: | G Thread NPT Thread | Coil: | Plastic Seal IP65 H Degree |
High Light: | hot water solenoid valve,solenoid valve steam |
PS series 2-way piston normally open steam hot water solenoid valve 1/2" ~ 2"
PS-series(NO)steam solenoid valve specification table
interface |
orifice (mm) |
Cv
|
working pressure (bar) |
max medium temp. ℃
|
coil |
normal order code
|
|||||||
min pressure |
max pressure |
coil insulation degree
|
power |
Plastic seal: IP65 H degree AC220V G thread
|
|||||||||
steam
|
high temperature liquid (viscosity≤20cst) |
VA
|
W
|
||||||||||
AC 220V |
DC 24V |
||||||||||||
AC | DC | AC | DC | brass | SS304 | ||||||||
1/2〃
|
15 | 4.8 | 0.4 | 8 | 8 | 8 | 8 | 180 | H | 23 | 28 | PS-15K-AC220V | PS-15JK-AC220V |
3/4〃
|
20 | 7.6 | 0.4 | 8 | 8 | 8 | 8 | 180 | H | 23 | 28 | PS-20K-AC220V | PS-20JK-AC220V |
1〃 | 25 | 12 | 0.4 | 8 | 8 | 8 | 8 | 180 | H | 23 | 28 | PS-25K-AC220V | PS-25JK-AC220V |
11/4〃
|
32 | 24 | 0.4 | 8 | 8 | 8 | 8 | 180 | H | 23 | 28 | PS-32K-AC220V | PS-32JK-AC220V |
11/2〃 | 40 | 30 | 0.4 | 8 | 8 | 8 | 8 | 180 | H | 23 | 28 | PS-40K-AC220V | PS-40JK-AC220V |
2〃 | 50 | 48 | 0.4 | 8 | 8 | 8 | 8 | 180 | H | 23 | 28 | PS-50K-AC220V | PS-50JK-AC220V |
Steam solenoid valve installation
1, in the lack of rigid pipe, it is recommended to use the valve before the pipe bracket, so as not to cause vibrations when the solenoid valve is working.
2, the working medium steam solenoid valve should be clean and free of particulate impurities, dirt and member of the electromagnetic valve on the filter surface, requiring regular clean.
3, when the steam solenoid valve fails to timely isolation solenoid valves, and ensure the normal operation, it is best to install a bypass device.
4, in the pipeline system, installed in the branch on the way solenoid valve diameter should be less than the main pipe valve diameter (Figure 2).
5, install the solenoid valve coil up and maintain the vertical position, the solenoid valve arrow or mark shall be consistent with the flow of the pipeline can not be installed in a splash of water or the leak.
6, steam solenoid valve can not be installed in the lower recesses of the pipe, so as to avoid steam condensate and impurities precipitated valve impede action.
7, ordinary type can not be used in explosion hazardous areas.
8, before the installation of the steam solenoid valves, pipes must be cleaned. It recommended before valve mounting filters, steam trap piping installation.
9, prior to installation, pay attention to see the product label, carefully read the instruction manual to determine whether the product meets the conditions of use.
10, before and after the steam solenoid valve pressure gauge to be installed on the pipe, in order to observe the pipeline pressure.
Founded in 1965, Yuyao No.4 Instrument Factory has been a professional manufacturer of solenoid valves and has enjoyed an excellent reputation through the past more than 50 years in China.
The company is equipped with superior production machines, advanced process flows, complete testing systems; the products have sophisticated structure, reliable performance, fine outlook and reasonable price, covering over 40 series and 3000 specifications, having been exported to more than twenty countries and areas, such as USA, France, UK, Germany, Italy, Australia, Russia, Taiwan, and the middle east countries etc., and our distributors spread all over the whole country.